Ht-instruments SOLAR I-V Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Nástroje Ht-instruments SOLAR I-V. HT instruments SOLAR I-V User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - I-V400 - SOLAR I-V

 Copyright HT ITALIA 2012 Release EN 1.05 - 28/05/2012 I-V400 - SOLAR I-V User manual

Strany 2

I-V400 - SOLAR I-V EN - 84.2. KEYBOARD DESCRIPTION The keyboard includes following keys: ON/OFF key to switch on/off the instrument ES

Strany 3

I-V400 - SOLAR I-V EN - 95. MAIN MENU Pressing the MENU/ESC key in any allowable condition of the instrument displays the main menu screen, in w

Strany 4

I-V400 - SOLAR I-V EN - 105.1.2. Measurement units This § allows setting the default measurement units of some internal parameters included in t

Strany 5

I-V400 - SOLAR I-V EN - 115.1.4. Remote unit This section allows selecting the type of remote unit to be used (if available) and setting the val

Strany 6

I-V400 - SOLAR I-V EN - 125.1.5. Irradiance 1. Move the cursor to “Irradiance” by means of the arrow keys (,) and confirm with ENTER. 2. The

Strany 7 - 2. GENERAL DESCRIPTION

I-V400 - SOLAR I-V EN - 135.2. EFF – SETTINGS FOR TESTING PV SYSTEMS (ONLY SOLAR I-V) Further in this manual, the acronym MPPT (Multiple Power

Strany 8 - 3. PREPARATION FOR USE

I-V400 - SOLAR I-V EN - 145.2.1.2. PV plant parameters 1. Press MENU key, move the cursor onto EFF by using the arrow keys (,) and confirm wi

Strany 9 - 4. DESCRIPTION OF PARTS

I-V400 - SOLAR I-V EN - 155.2.2. Settings for PV with single/multi MPPT inverter – single/three phase AC output See § 11.2 for further details

Strany 10

I-V400 - SOLAR I-V EN - 165.2.2.2. PV plant parameters 1. Press MENU key, position the cursor onto EFF by using the arrow keys (,) and confi

Strany 11 - 5. MAIN MENU

I-V400 - SOLAR I-V EN - 175.2.2.3. MPP300 status If SOLAR I-V is near MPP300, the general parameters of MPP300 may be displayed. 1. Position th

Strany 13 - CAUTION

I-V400 - SOLAR I-V EN - 185.2.3. Selection of the compensation relationship of temperature effects This option allows selecting the relationshi

Strany 14

I-V400 - SOLAR I-V EN - 195.3. DB – MODULE DATABASE The meter allows defining up to 30 different PV modules, further to a DEFAULT situation (no

Strany 15

I-V400 - SOLAR I-V EN - 205.3.1. How to define a new PV module 1. Move the cursor to “DB” by means of the arrow keys (,) and confirm with EN

Strany 16

I-V400 - SOLAR I-V EN - 215.3.2. How to modify a PV module 1. Select the PV module to be modified from the internal database by means of arrow

Strany 17

I-V400 - SOLAR I-V EN - 226. HOW TO OPERATE 6.1. TESTING PV SYSTEMS (ONLY SOLAR I-V) For the sake of simplicity, further in this manual, the w

Strany 18

I-V400 - SOLAR I-V EN - 236.1.1. Testing of PV systems with single-MPPT inverter - single-phase AC output The SOLAR I-V meter (master) can perf

Strany 19

I-V400 - SOLAR I-V EN - 245. In case of inverters provided with more than one power tracker (MPPT), only leave the string corresponding to the

Strany 20

I-V400 - SOLAR I-V EN - 2513. The display shows the first screen containing the values of the electrical parameters on the DC side of the invert

Strany 21

I-V400 - SOLAR I-V EN - 2617. At any time it will be possible to analyze the current recording status by pressing the MENU key. The following in

Strany 22

I-V400 - SOLAR I-V EN - 276.1.2. Test PV systems with single/multi-MPPT inverter – single/three-phase AC output The instrument SOLAR I-V, used

Strany 23

I-V400 - SOLAR I-V EN - 1Table of contents: 1. SAFETY PRECAUTIONS AND PROCEDURES ... 31

Strany 24 - 6. HOW TO OPERATE

I-V400 - SOLAR I-V EN - 28 CAUTION  When SOLAR I-V is set in order to use MPP300 as a remote unit, ALL connections relevant to electrical qu

Strany 25

I-V400 - SOLAR I-V EN - 299. Connect the output connector of the DC clamp to the IDC1 input of unit MPP300. CAUTION BEFORE CONNECTING THE D

Strany 26

I-V400 - SOLAR I-V EN - 30 18. On SOLAR I-V, press key () to access the second screen which contains the values of the output DC parameters of

Strany 27

I-V400 - SOLAR I-V EN - 31 22. At any time it will be possible to analyze the current recording status by pressing the MENU key. The following i

Strany 28

I-V400 - SOLAR I-V EN - 32 32. To stop testing, press the GO/STOP key on instrument SOLAR I-V and confirm pressing ENTER that you want to stop r

Strany 29

I-V400 - SOLAR I-V EN - 33 6.2. I-V CURVE MEASUREMENT The meter can perform I-V curve tests by using one of the herewith modes:  I-V curve t

Strany 30

I-V400 - SOLAR I-V EN - 349. Press ENTER key, select the “Settings” item and confirm again with ENTER to access the next screen which allows set

Strany 31

I-V400 - SOLAR I-V EN - 3519. Connect the meter to the module/string under test as shown in Fig. 7a. In particular, connect the negative output

Strany 32

I-V400 - SOLAR I-V EN - 3622. At the end of test, the values of typical parameters (all referred to a single module in standard conditions STC)

Strany 33

I-V400 - SOLAR I-V EN - 376.2.2. I-V curve measurement by use of remote unit SOLAR-02 The I-V curve test with Irr/Temp measurement by use of re

Strany 34

I-V400 - SOLAR I-V EN - 27. STORING DATA ...

Strany 35

I-V400 - SOLAR I-V EN - 389. The instrument displays a screen similar to the one reported here to the side, where:  Vdc = DC output voltage fr

Strany 36 - Rs : Auto

I-V400 - SOLAR I-V EN - 3916. Mount the M304 (inclinometer) supplied accessory, place and hold it on the plane of module. Verify that the sun sh

Strany 37

I-V400 - SOLAR I-V EN - 4021. The instrument displays a screen similar to the one reported here to the side, where:  Vdc = DC output voltage f

Strany 38

I-V400 - SOLAR I-V EN - 416.2.2.2. I-V curve test by remote unit SOLAR-02 in synchro recording This mode, which consists in an independent reco

Strany 39

I-V400 - SOLAR I-V EN - 4210. The instrument displays a screen similar to the one reported here to the side, where:  Vdc = DC output voltage f

Strany 40

I-V400 - SOLAR I-V EN - 4317. Mount the M304 (inclinometer) supplied accessory, place and hold it on the plane of module. Verify that the sun sh

Strany 41

I-V400 - SOLAR I-V EN - 4422. The instrument displays a screen similar to the one reported here to the side, where:  Vdc = DC output voltage f

Strany 42

I-V400 - SOLAR I-V EN - 4525. At the end of test, based on the descriptions of previous points, the message “STC Data available after Stop rec”

Strany 43

I-V400 - SOLAR I-V EN - 466.2.3. Meaning of measurement results The parameter measured and calculated by meter have the following meaning: Par

Strany 44

I-V400 - SOLAR I-V EN - 476.2.4. Serial resistance Rs The serial resistance Rs is one of the typical elements of PV modules which can affect t

Strany 45

I-V400 - SOLAR I-V EN - 31. SAFETY PRECAUTIONS AND PROCEDURES The word “instrument” in this manual means generically both the model I-V400 and

Strany 46

I-V400 - SOLAR I-V EN - 488. Press ENTER key and by means of arrow keys (,) select the item “Meas. Type ” 9. By means of arrow key  access

Strany 47 - Results @ OPC

I-V400 - SOLAR I-V EN - 4915. After connection to the panel, the real time values are shown by meter:  Open voltage of module installation 

Strany 48

I-V400 - SOLAR I-V EN - 506.3. QUICK CHECK ON PV MODULES AND STRINGS (IVCK) 6.3.1. General information This function permits to carry out a qui

Strany 49

I-V400 - SOLAR I-V EN - 516.3.2. Preliminary settings 1. Turn the instrument on by pressing ON/OFF key. 2. Press ESC/MENU to display the main m

Strany 50

I-V400 - SOLAR I-V EN - 526.3.3. Fast check IVCK without irradiance measurement CAUTION  The maximum voltage among inputs P1, P2, C1 and

Strany 51

I-V400 - SOLAR I-V EN - 539. The initial screen under IVCK mode displays the values of:  Module under use  The average values of Voc and Isc

Strany 52

I-V400 - SOLAR I-V EN - 546.3.4. Fast check IVCK with irradiance measurement CAUTION  The maximum voltage among inputs P1, P2, C1 and C2

Strany 53

I-V400 - SOLAR I-V EN - 559. Connect irradiance probes and temperature probe (if necessary) according to previous pictures and to effected set

Strany 54

I-V400 - SOLAR I-V EN - 566.3.5. Reset Media If irradiance values are measured the instrument provides an outcome comparing the measured values

Strany 55

I-V400 - SOLAR I-V EN - 57 6.4. LIST OF DISPLAY MESSAGES MESSAGE DESCRIPTION Voltage too low Check the voltage between C1 and C2 input termina

Strany 56

I-V400 - SOLAR I-V EN - 41.2. DURING USE We recommend to carefully read the following recommendations and instructions: CAUTION  Failure to

Strany 57

I-V400 - SOLAR I-V EN - 587. STORING DATA The meter allows storing 99 results of PV checks (only SOLAR I-V) and 249 tests of I-V curve in its in

Strany 58 - 15/05/10 15:34:26

I-V400 - SOLAR I-V EN - 597.3. MANAGING THE RESULTS 7.3.1. Recall data of PV checks at display (solo SOLAR I-V) 1. Press ESC/MENU key to back

Strany 59 - MESSAGE DESCRIPTION

I-V400 - SOLAR I-V EN - 607.3.2. Recall data of I-V curve tests at display 1. Press ESC/MENU key to back to the main menu, select the “MEM” it

Strany 60 - 7. STORING DATA

I-V400 - SOLAR I-V EN - 617.3.2.1. View data – Numerical screens 1. Select a row corresponding to a saved result and press ENTER to access the

Strany 61

I-V400 - SOLAR I-V EN - 627.3.2.2. View data – Graphic screens of I-V curve 1. With screen of numerical values relative to standard conditions

Strany 62

I-V400 - SOLAR I-V EN - 637.3.2.3. View data – Graphic screens of power 1. With screen of numerical values measured by the meter select the it

Strany 63

I-V400 - SOLAR I-V EN - 647.3.3. Delete data 1. Press ENTER key in the memory § to show the submenu 2. Select the “Delete” item and press the a

Strany 64

I-V400 - SOLAR I-V EN - 658. CONNECTING THE INSTRUMENT TO A PC CAUTION  The connection between instrument and PC is realized by means of ca

Strany 65

I-V400 - SOLAR I-V EN - 669. MAINTENANCE 9.1. GENERAL The instrument you purchased is a precision instrument. When using and storing it, please

Strany 66

I-V400 - SOLAR I-V EN - 6710. TECHNICAL SPECIFICATIONS 10.1. YIELD TEST TECHNICAL FERATURES (ONLY SOLAR I-V) Accuracy is calculated as [%reading

Strany 67 - PC – RS232

I-V400 - SOLAR I-V EN - 52. GENERAL DESCRIPTION 2.1. INTRODUCTION The instrument was designed to perform complete yield test on single-phase (an

Strany 68 - 9. MAINTENANCE

I-V400 - SOLAR I-V EN - 6810.2. I-V TEST TECHNICAL FEATURES (I-V AND IVCK) I-V: DC Voltage @ OPC Range [V] (***) Resolution [V] Uncertainty (

Strany 69 - 10. TECHNICAL SPECIFICATIONS

I-V400 - SOLAR I-V EN - 6910.4. GENERAL CHARACTERISTICS Display and memory Type of display: LCD custom, 128x128 pxl, backlighted Memory capa

Strany 70

I-V400 - SOLAR I-V EN - 7011. APPENDIX 11.1. TESTING PHOTOVOLTAIC SYSTEMS According to the requirements of the laws in force, the result of the

Strany 71

I-V400 - SOLAR I-V EN - 7111.2. NOTES ON MPPT (MAXIMUM POWER POINT TRACKER) Solar irradiation on a surface such as the surface of a photovoltaic

Strany 72 - 11. APPENDIX

I-V400 - SOLAR I-V EN - 72The reason why MPPTs are used is simple: a photovoltaic system without MPPTs may operate anyway; however, with the sam

Strany 73

I-V400 - SOLAR I-V EN - 7312. SERVICE 12.1. WARRANTY CONDITIONS This instrument is guaranteed against any defect in material and manufacturing

Strany 74

Via della Boaria 40 48018 – Faenza (RA) - Italy Tel: +39-0546-621002 (4 linee r.a.) Fax: +39-0546-621144 email: [email protected] http://www.ht-instrum

Strany 75 - 12. SERVICE

I-V400 - SOLAR I-V EN - 63. PREPARATION FOR USE 3.1. INITIAL CHECKS Before shipment, the instrument’s electronics and mechanics have been caref

Strany 76

I-V400 - SOLAR I-V EN - 74. DESCRIPTION OF PARTS 4.1. INSTRUMENT DESCRIPTION CAPTION: 1. Inputs 2. Display 3. Connector for opto insulated cab

Příbuzné modely I-V400

Komentáře k této Příručce

Žádné komentáře