Strany 2

M70 EN - 92. Short-circuit the cable ends with each other as shown in Fig. 5 making sure that the metallic parts of test probes and crocodiles a

Strany 3

M70 EN - 104.5. Lo: CONTINUITY TEST ON EARTH, PROTECTIVE AND EQUALIZING POTENTIAL CONDUCTORS The measurement is performed with a test current h

Strany 4

M70 EN - 114.5.1. "ZERO" mode 1. Any addition or replacement of cables, extensions and croco clips nullify the previous calibration an

Strany 5 - 3. PREPARATION FOR USE

M70 EN - 124.6. M: INSULATION RESISTANCE MEASUREMENT TEST VOLTAGE 250V, 500V, 1000V DC The measurement is performed according to IEC/EN61557-2

Strany 6 - 4. OPERATING INSTRUCTIONS

M70 EN - 13 CAUTION The message on the display means that the instrument is discharging eventual capacitors. During this phase never disc

Strany 7

M70 EN - 145. MAINTENANCE 5.1. GENERAL This is a precision instrument. Strictly follow the instructions for use and storage reported in this manu

Strany 8

M70 EN - 156. TECHNICAL SPECIFICATIONS 6.1. CHARACTERISTICS Accuracy is indicated as [%reading + (digit number*resolution)] at 23°C±5°, RH <70

Strany 9

M70 EN - 166.1.1. Electrical Conversion: Average value Display refreshing rate: 2 times per second 6.1.2. Safety standards The instrument compl

Strany 10 - Input voltage

M70 EN - 177. SERVICE 7.1. WARRANTY CONDITIONS This instrument is guaranteed against material or production defects, in accordance with our gener

Strany 11 - CAUTION

M70 EN - 1Table odf Contents 1. SAFETY PRECAUTIONS AND PROCEDURES ... 21.1. Preliminary

Strany 12

M70 EN - 21. SAFETY PRECAUTIONS AND PROCEDURES This instrument complies with safety IEC/EN61557-1 and IEC/EN61010-1 guidelines related to electro

Strany 13

M70 EN - 31.2. DURING USE Read the recommendations which follow and the instructions in this manual: CAUTION An improper use may damage t

Strany 14

M70 EN - 42. GENERAL DESCRIPTION Dear Customer, the instrument you have purchased, whether used according to the instructions given in this manua

Strany 15 - 5. MAINTENANCE

M70 EN - 54. OPERATING INSTRUCTIONS 4.1. INSTRUMENT - DESCRIPTION CAPTION: 1. Inputs 2. Inputs 3. Display 4. ON/OFF key 5. LOCK key 6. ZERO a

Strany 16 - 6. TECHNICAL SPECIFICATIONS

M70 EN - 64.2. : DC VOLTAGE MEASUREMENT CAUTION The maximum input voltage is 550+10%V. Don’t try to measure higher voltages to avoid ri

Strany 17

M70 EN - 74.3. : AC VOLTAGE MEASUREMENT CAUTION The maximum input voltage is 550+10%V. Don’t try to measure higher voltages to avoid ri

Strany 18 - 7. SERVICE

M70 EN - 84.4.  : RESISTANCE MEASUREMENT AND CONTINUITY TEST CAUTION Before taking resistance measurements make sure that the circuit